AC input power must be disconnected before any wiring to the AC motor drive is made.

Even if the power has been turned off, a charge may still remain in the DC-link capacitors with hazardous voltages before the POWER LED is OFF. Please do not touch the internal circuit and components.

There are highly sensitive MOS components on the printed circuit boards.

These components are especially sensitive to static electricity. Please do not touch these components or the circuit boards before taking anti-static measures. Never reassemble internal components or wiring.

Ground the AC motor drive using the ground terminal. The grounding method must comply with the laws of the country where the AC motor drive is to be installed.

DO NOT install the AC motor drive in a place subjected to high temperature, direct sunlight and inflammables.

Never connect the AC motor drive output terminals U/T1, V/T2 and W/T3 directly to the AC mains circuit power supply.

Only qualified persons are allowed to install, wire and maintain the AC motor drives.

Even if the 3-phase AC motor is stop, a charge may still remain in the main circuit terminals of the AC motor drive with hazardous voltages.

If the AC motor drive is stored in no charge condition for more than 3 months, the ambient temperature should not be higher than 30 °C. Storage longer than one year is not recommended, it could result in the degradation of the electrolytic capacitors.

NOTE The content of this manual may be revised without prior notice. Please consult our distributors or download the most updated version at http://www.delta.com.tw/industrialautomation

SUMMARY OF UPDATES0-1
CHAPTER 1 INTRODUCTION1-1
CHAPTER 2 INSTALLATION2-1
CHAPTER 3 UNPACKING3-1
CHAPTER 4 WIRING4-1
CHAPTER 5 MAIN CIRCUIT TERMINALS5-1
CHPATER 6 CONTROL TERMINALS6-1
CHAPTER 7 OPTIONAL ACCES SORIES7-1
CHAPTER 8 OPTION CARDS8-1
CHAPTER 9 SPECIFICATION9-1
CHAPTER 10 DIGITAL KEYPAD10-1
CHAPTER 1 SUMMARPY OF PARAMETERS1-1
CHPAPTER 12 DESCRIPTION OF PARAMETER SETTINGS12-1
CHAPTER 13 WARNING CODES13-1
CHAPTER 14 FAULT CODES AND DESCRIPTIONS14-1
CHAPTER 15 CANOPEN OVERVIEW15-1
CHAPTER 16 PLC FUNCTION16-1

Table of Contents

Application Control BD V1.0; Keypad V1.0;

Summary of Updates C2000 Series

Summary of Updates

The following changes summarize the differences to the C2000 Simplified Manual, Version 5011694700.

Chatpers Changes Detail

[Table of Content] New

New Chapters: • Chapter 2 Installation

• Chapter 7 Optional Accessories

• Chapter 12 Description of Parameter Settings

• Chapter 15 CANopen Overview

• Chapter 16 PLC Function

• (Applicable model, AC motor drive selection) Applicable model AC motor drive selection

New Frame FRAME A~H

KPC-CC01 digital keypad [01 Introduction]

Update Serial number

New Mounting clearances and wiring information [02 Installation]

Update Unpacking details moved to CH3

[03 Unpacking] New FRAME F~H

FRAME H secure the drive FRAME F~H lifting weight

[04Wiring] New RB-RC power protection system diagram

Updates Wiring diagram 1, 2

Control circuit description Figure1,2 Figure 3 FRAME E-H DC-LINK

New Main circuit terminal specification FRAME F~H

Main circuit terminal diagram 3 Terminal signs +1, - and description

[05 Main circuit terminal] Update

Main circuit terminal specifications Frame A~E (max. and min. wire gauge,torque, note, diagram)

Steps to removes the key cover and wiring New

Removable terminal block figure

[06 Control circuit terminal]

Update Control terminal specification: wire gauge, torque,

Descripton and factory settings: MI11~MI8 terminals, SG+ & SG- terminals Steps to remove the terminal block

[08 Option cards] New Steps to remove key cover

EMC-D611A I/O & Relay extension card EMC-PG01L PG card and wiring diagrams(can be operate by Pr.10-0~10-02) EMC-PG01O PG card and wiring diagrams(can be operate by Pr.10-0~10-02) EMC-PG01U: description, wiring diagram, terminal Screw Sepecifications EMC-PG01R: description, wiring diagram, terminal Screw Sepecifications CMC-MOD01: feature, product file, CMC-MOD01 installation to C2000, parameter setting for Ethernet, removal, basic register, LED indicator& troubleshoots CMC-PD01: feature, product file, installation, LED indicator& troubleshoots CMC-DN01: feature, product file, LED indicator& troubleshoots CMC-EIP01: feature, product file, installation, Connecting CMC-EIP01 to VFD-C2000, parameter setting for Ethernet, removal, basic register, LED indicator& troubleshoots

EMC-COP01: RJ45 Pin definition, Specification

Update RJ45 (Socket) for digital keypad

Option card diagrams for Slot 1~3 EMC-D42A: Descriptons for COM and MI10~MI13 EMC-R6AA: Description EMC-PG01O PG OUT V+, V-, A/O, B/O, Z/O

Remove ABZ1 Encoder signal type, AB2 Pulse signal type

230V FRAME F specification 460V FRAME F~H specification New

Operation temperature and protection level

230V/460V Nomal load: carrier frequency Operational voltage range

230V EMC Filter EMI Filter

460V EMI Filter Description and Note

Update

Control method Certification

230V/460V Heavy load& Normal load: load capacity and max. output frequency (Hz)

Torque characteristic Overload capacity Ambient temperature

[09 Specification]

Delete

*Reduced by 2%Irated/1℃

New Digital Keypad: KPC-CC01 Function

Keypad picture Descriptions of Keypad Functions

Change LED keypad to KPC-CE01 CANopen~”RUN” CANopen~”ERR”

Update

ONLY LED change to KPC-CE01

[10 Digital Keypad]

Remove Digital keypad operation procedure

Group 0 Pr.0-0 Settings: 39, 41, 43, 45, 47, 49, 51, 93 Pr.0-04 Settings: 2~8, 21,24~31 Pr 0-05 Pr.0-25~Pr.0-50

Group 5 Pr.05-0 Settings: 4, 5, 6, 12 Pr.05-3~05-43

New Parameters

[1 Summary of Parameters]

Pr00-09 Reserved Pr.0-10 Settings: 1~3

1-15HP [1-20HP]2~15KHz
20-50HP [25-100HP]2~10KHz

Pr.0-1 Settings: 0~5 Pr. 0-12 point-to-point position mode Pr.0-13 Settings: 0~2 Pr.0-14 Reserved Pr.0-17 Normal load 230V (460V) 60-100HP [125-475HP] 2~09KHz

Heavy load 1-475HP 2~6KHz

Summary of Updates C2000 Series

Pr.0-19 PLC Command Mask Pr.0-20 Source of Master Frequency Command(AUTO)

Pr.0-21 Settings: 0~5 Pr.0-24 Memory of Frequency Command Pr. 02-01~02-08 Settings: 6, 10, 18, 31~3, 35, 37, 41~47, 49, 54~70 Pr.0-14 Reserved

Group 01 Pr. 01-02~01-06, 01-20~01-21, 01-36~01-40: Factory Settings

Goup 02 Pr.02-09 1: up/down constant speed (Pr.02-10) Pr.02-1 Pr.02-13~02-17 Settings: 10, 13, 14, 39, 40, 43~49, 51, 52 Pr.02-19 Terminal counting value attained (returns to 0) Pr.02-20 Preliminary counting value attained (not return to 0) Pr.02-3 Output Current Level Setting for Multi-function External Terminals Pr.02-34 Pr.02-35 Pr.02-37 Pr.02-48

Group 04 Pr.04-15~04-29

Group 05 Pr.05-01 Settings: 10~120% of drive’s rated current Pr.05-06~05-09, 05-18~05-21 setting range Pr.05-12~05-13

Group 07 Pr.07-05 Pr.07-07 Pr.07-10 Pr.07-24~07-27 Pr.07-29 Pr.07-31~07-3

Group 08 Pr.08-0 Pr.08-20

Group 09 Pr.09-30 Pr.09-35 Pr.09-37~09-39 Pr.09-43 Pr.09-45

Group 10 Pr.10-0 Pr.10-17~10-18 Pr.10-21

Group 1 Pr.1-0 Pr.1-03~1-06 Pr.1-08

Pr.1-10 Pr.1-24 Pr.1-28~1-34 Pr.1-40

New LCM display screen example

Error code: “SE3”, “PGFB”, “Cldn”, “Cadn”, “CFrn”, “PLSF”, “PCGd”, “PCbF”, “PCnL”, “PCCt”, “PCSF”, “PCSd”, “PCAd”, “Ecby”

Update LED display content “ANL” description

[13 Warning Codes]

Remove LCM display example All display icons

New Fault display screen example

Fault code: “ovA”, “ovd”, “ovn”, “ovS”, “PWR”, “uC”, “LMIT”, “ryF”, “PGF5”, “ocU”, “ocV”, “OPHL”, “OPHL”, “OPHL”, “TRAP”

Update LCM display icons

Fault codes: “CE1”, “CE2”, “CE3”, “CE4”, “CE10”, “CP10” , “dEb”, “Uocc” A, “Vocc” B, “Wocc” C

[14 Fault Codes and Descriptions]

Remove LED display content

Fault code: “UC1”, “UC2”

Chapter 1 Introduction C2000 Series

Chapter 1 Introduction

Receiving and Inspection After receiving the AC motor drive, please check for the following:

1. Please inspect the unit after unpacking to assure it was not damaged during shipment. 2. Make sure that the part number printed on the package corresponds with the part number indicated on the nameplate. 3. Make sure that the voltage for the wiring lie within the range as indicated on the nameplate. 4. Please install the AC motor drive according to this manual. 5. Before applying the power, please make sure that all the devices, including power, motor, control board and digital keypad, are connected correctly. 6. When wiring the AC motor drive, please make sure that the wiring of input terminals “R/L1, S/L2,

T/L3” and output terminals”U/T1, V/T2, W/T3” are correct to prevent drive damage. 7. When power is applied, select the language and set the parameter groups via the digital keypad (KPC-CC01). 8. After applying the power, please trial run with the low speed and then increase the speed gradually to the desired speed.

Nameplate Information

MODEL:VFD007C43A

Normal Duty: 3PH 380-480V 50/60Hz 4.3A Heavy Duty: 3PH 380-480V 50/60Hz 4.1A

Version:

Normal Duty: 3PH 0-480V 3A 2.4KVA 1HP Heavy Duty: 3PH 0-480V 2.9A 2.3KVA 1HP

Normal Duty: 0-600Hz Heavy Duty: 0-300Hz

AC Drive Model Input Voltage/Current

Output Voltage/ Current Frequency Range

Firmware Version Certifications

Serial Number

Chapter 1 Introduction C2000 Series

VFD007C43A

Model Name

23:230V 3-PHASE 43:460V 3-PHASE

Version type Input voltage

C2000 series Applicable motor capacity

Refer to the specifications for details Series name(Variable Frequency Drive)

Serial Number 007C43A0 T 9 30 0002

Production number

Production week Production year

Production factory Model number

T: Tauyuan W: Wujian S: Shanghai

Chapter 1 Introduction C2000 Series

Dimensions

Frame A VFD007C23A; VFD007C43A/E; VFD015C23A; VFD015C43A/E; VFD022C23A; VFD022C43A/E; VFD037C23A; VFD037C43A/E; VFD040C43A/E; FD055C43A/E

Unit: m [inch] Frame W H D W1 H1 D1* S1 Φ1 Φ2 Φ3

130.0 [5.12] 250.0 [9.84] 170.0 [6.69] 116.0 [4.57] 236.0 [9.29] 45.8 [1.80] 6.2 [0.24] 2.2 [0.87] 34.0 [1.34] 28.0 [1.10]

D1*: Flange mounting NOTE: Model VFD007C43E; VFD015C43E; VFD022C43E; VFD037C43E; VFD040C43E; VFD055C43E will be available for ordering soon. Please contact your local distributor or Delta representative for detailed launch schedule.

Chapter 1 Introduction C2000 Series

Frame B VFD055C23A; VFD075C23A; VFD075C43A/E; VFD110C23A; VFD110C43A/E; VFD150C43A/E

Detail A (Mounting Hole) Detail B (Mounting Hole)

See Detail A

See Detail B

Unit: m [inch] Frame W H D W1 H1 D1* S1 Φ1 Φ2 Φ3

190.0 [7.48] 320.0 [12.60]190.0 [7.48] 173.0 [6.81] 303.0 [1.93]7.9 [3.07] 8.5 [0.3] 2.2 [0.87] 34.0 [1.34] 28.0

[1.10]

D1*: Flange mounting NOTE: Model VFD075C43E; VFD110C43E; VFD150C43E will be available for ordering soon. Please contact your local distributor or Delta representative for detailed launch schedule.

Chapter 1 Introduction C2000 Series

Frame C VFD150C23A; VFD185C23A; VFD185C43A/E; VFD220C23A; VFD220C43A/E; VFD300C43A/E

Detail A (Mounting Hole) Detail B (Mounting Hole)

See Detail A

See Detail B

Unit: m [inch] Frame W H D W1 H1 D1* S1 Φ1 Φ2 Φ3

250.0 [9.84] 40.0 [15.75]210.0 [8.27] 231.0 [9.09] 381.0 [15.0]92.9 [3.6] 8.5 [0.3] 2.2 [0.87] 34.0 [1.34] 50.0 [1.97]

D1*: Flange mounting

NOTE: Mode VFD185C43E; VFD220C43E; VFD300C43E will be available for ordering soon. Please contact your local distributor or Delta representative for detailed launch schedule.

Chapter 1 Introduction C2000 Series

Frame D D1: VFD300C23A; VFD370C23A; VFD370C43A; VFD450C43A; VFD550C43A; VFD750C43A D2: VFD300C23E; VFD370C23E; VFD370C43E; VFD450C43E; VFD550C43E; VFD750C43E

W W1

H3 D1

H H1H2

D2 SEE DETAIL A

S1S1

D1*: Flange mounting

Unit: m [inch]

Frame W H D W1 H1 H2 H3 D1* D2 S1 S2 Φ1 Φ2 Φ3

330.0 [12.9] 688.3 [27.10] 275.0 [10.83] 285.0 [1.2] 550.0 [21.65] 525.0 [20.67]492.0[19.37]107.2[4.2]16.0 [0.63] 1.0 [0.43]18.0 [0.71] 76.2 [3.0] 34.0 [1.34]2.0 [0.87]

Chapter 1 Introduction C2000 Series

Frame E E1: VFD450C23A; VFD550C23A; VFD750C23A; VFD900C43A; VFD1100C43A E2: VFD450C23E; VFD550C23E; VFD750C23E; VFD900C43E; VFD1100C43E

W1 W

H2 H1 H3 H

D1 D

Unit: m [inch] Frame W H D W1 H1 H2 H3 D1*D2 S1, S2 S3 ψ1 ψ2 ψ3

E1 370.0

[14.57] - 300.0

D1*: Flange mounting

Chapter 1 Introduction C2000 Series

Frame F F1: VFD900C23A; VFD1320C43A; VFD1600C43A; F2: VFD900C23E; VFD1320C43E; VFD1600C43E

H1H2

S1 S1 D2

WW1 D D1

H3 H

See Detail A

See Detail B

Detail A (Mounting Hole) Detail B (Mounting Hole)

Unit: m [inch] Frame W H D W1 H1 H2 H3 D1* D2 S1 S2 S3

F1 420.0 [16.54] 300.0 [1.81] 380.0 [14.96] 800.0[31.50]770.0[30.32]717.0[28.23]124.0[4.8]18.0 [0.71] 13.0 [0.51] 25.0 [0.98]18.0

F2 420.0 [16.54] 940.0 [37.0] 30.0 [1.81] 380.0 [14.96] 800.0[31.50]770.0[30.32]717.0[28.23]124.0[4.8]18.0 [0.71] 13.0 [0.51] 25.0 [0.98]18.0

Frame ψ1 ψ2 ψ3
F1 92.0 [3.62] 35.0 [1.38] 2.0 [0.87]
F2 92.0 [3.62] 35.0 [1.38] 2.0 [0.87]

D1*: Flange mounting

Chapter 1 Introduction C2000 Series

Frame G G1: VFD1850C43A; VFD2200C43A; G2: VFD1850C43E; VFD2200C43E

W1 W

H2 H1H H3

Unit: m [inch] Frame W H D W1 H1 H2 H3 S1 S2 S3 ψ1 ψ2 ψ3

G1 500.0

[19.69] - 397.0 [15.63] 440.0 [217.32] 1000.0[39.37]963.0[37.91]913.6[35.97]13.0[0.51]26.5[1.04]27.0 [1.06] - - -

Chapter 1 Introduction C2000 Series

Frame H H1: VFD2800C43A; VFD3150C43A; VFD3550C43A H2: VFD2800C43E-1; VFD3150C43E-1; VFD3550C43E-1 H3: VFD2800C43E; VFD3150C43E; VFD3550C43E

Unit: m [inch] Frame W H D W1 W2 W3 W4 W5 W6 H1 H2 H3 H4

H1 700.0

[1.42]- - - - 1435.0

H2 700.0

H3 700.0 [27.56] 1745.0 [68.70] 404.0 [15.91] 800.0 [31.50] - - 500.0[19.69]630.0[24.80]760.0[29.92]1729.0 [68.07] - - 1701.6 [6.9]

Chapter 1 Introduction C2000 Series

Frame H5 D1 D2 D3 D4 D5 D6 S1 S2 S3 ψ1 ψ2 ψ3

H1 1346.6

H2 1346.6

H3 1346.6

Chapter 1 Introduction C2000 Series

Digital Keypad KPC-CC01

Chapter 2 Installation C2000 Series

Chapter 2 Installation

Airflow direction: (Blue arrow) inflow(Red arrow) outflow

The appearances shown in the following figures are for reference only.

Single drive: installation

(Frame A-H) Side-by-side installation(Frame A-C)

Multiple drives: side-by-side installation(Frame A,B,C, G, H) Multiple drives: side-by-side installation (Frame D, E, F) Install a barrier between the drives.

Chapter 2 Installation C2000 Series

Ta: Frame A~GTa*: Frame H

Multiple drives side-by-side installation in rows (Frame A,B,C ) For installation in rows, it is recommended installing a barrier between the drives. Adjust the size/depthof the barrier till the temperature measured at the fan’s inflow side is lower than the operation temperature. Operation temperature is the defined as the temperature measured 50mm away from the fan’s inflow side. (As shown in the figure below)

Minimum mounting clearance

Frame A (m) B (m) C (m) D (m) A~C 60 30 10 0 D~F 100 50 - 0 G 200 100 - 0 H 350 0 0 200 (100, Ta=40℃)

Frame A VFD007C23A; VFD007C43A/E; VFD015C23A; VFD015C43A/E; VFD022C23A; VFD022C43A/E; VFD037C23A; VFD037C43A/E; VFD040C43A/E; VFD055C43A/E;

Frame B VFD055C23A; VFD75C23A; VFD075C43A/E; VFD110C23A; VFD110C43A/E; VFD150C43A/E;

Frame C VFD150C23A; VFD185C23A; VFD185C43A/E; VFD220C23A; VFD220C43A/E; VFD300C43A/E;

Frame D VFD300C23A/E; VFD370C23A/E; VFD370C43A/E; VFD450C43A/E; VFD550C43A/E; VFD750C43A/E;

Frame E VFD450C23A/E; VFD550C23A/E; VFD750C23A/E; VFD900C43A/E; VFD1100C43A/E; Frame F VFD900C23A/E; VFD1320C43A/E; VFD1600C43A/E; Frame G VFD1850C43A; VFD2200C43A; VFD1850C43E; VFD2200C43E;

Frame H VFD2800C43A; VFD3150C43A; VFD3550C43A; VFD2800C43E-1; VFD3150C43E-1; VFD3550C43E-1;VFD2800C43E; VFD3150C43E; VFD3550C43E;

NOTE 1. It is the minimum distance required for frame A~D. If drives are installed closer than the minimum mounting clearance, the

fan may not function properly

2. Model VFD007C43E; VFD015C43E; VFD022C43E; VFD037C43E; VFD040C43E; VFD055C43E; VFD075C43E;

VFD110C43E; VFD150C43E; VFD185C43E; VFD220C43E; VFD300C43E will be available for ordering soon. Please contact your local distributor or Delta representative for detailed launch schedule,

Chapter 2 Installation C2000 Series

NOTE ※ The mounting clearances shown in the left figure are NOT for installing the drive in a confined space (such as cabinet or electric box). When installing in a confined space, besides the same minimum mounting clearances, it needs to have the ventilation equipment or air conditioner to keep the surrounding temperature lower than the operation temperature.

(Parte 1 de 3)

Comentários